Testing Standard Pneumatic Secondary Valves
By Bill Maguire

[ Ref. Skip Downing in 180502 MMDigest ]

I find that the best way to test a double-valve Standard or
Autopiano stack is to do it with the primary valves connected.
The pneumatics and deck boards are not attached while checking
the valves.

I think the main reason your pneumatics are a bit sluggish or
"leisurely" is because when secondary valves are checked without
the primaries attached there is no bleed.

Bill Maguire
New York


(Message sent Sat 5 May 2018, 21:41:00 GMT, from time zone GMT-0400.)

Key Words in Subject:  Pneumatic, Secondary, Standard, Testing, Valves

Home    Archives    Calendar    Gallery    Store    Links    Info   


Enter text below to search the MMD Website with Google



CONTACT FORM: Click HERE to write to the editor, or to post a message about Mechanical Musical Instruments to the MMD

Unless otherwise noted, all opinions are those of the individual authors and may not represent those of the editors. Compilation copyright 1995-2024 by Jody Kravitz.

Please read our Republication Policy before copying information from or creating links to this web site.

Click HERE to contact the webmaster regarding problems with the website.

Please support publication of the MMD by donating online

Please Support Publication of the MMD with your Generous Donation

Pay via PayPal

No PayPal account required

                                     
Translate This Page